SECTION/RULE §113.2128 - What continuous emission monitoring systems must I install for gaseous pollutants?
Chapter Review Date 11/10/2023

(a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for oxygen (or carbon dioxide), sulfur dioxide, and carbon monoxide. If you operate a Class I municipal waste combustion unit, also install, calibrate, maintain, and operate a continuous emission monitoring system for nitrogen oxides. Install the continuous emission monitoring systems for sulfur dioxide, nitrogen oxides, and oxygen (or carbon dioxide) at the outlet of the air pollution control device.(b) You must install, evaluate, and operate each continuous emission monitoring system according to the "Monitoring Requirements" in 40 Code of Federal Regulations (CFR) §60.13.(c) You must monitor the oxygen (or carbon dioxide) concentration at each location where you monitor sulfur dioxide and carbon monoxide. Additionally, if you operate a Class I municipal waste combustion unit, you must also monitor the oxygen (or carbon dioxide) concentration at the location where you monitor nitrogen oxides.(d) You may choose to monitor carbon dioxide instead of oxygen as a diluent gas. If you choose to monitor carbon dioxide, then an oxygen monitor is not required and you must follow the requirements in §113.2133 of this title (relating to What must I do if I choose to monitor carbon dioxide instead of oxygen as a diluent gas?).(e) If you choose to demonstrate compliance by monitoring the percent reduction of sulfur dioxide, you must also install continuous emission monitoring systems for sulfur dioxide and oxygen (or carbon dioxide) at the inlet of the air pollution control device.(f) If you prefer to use an alternative sulfur dioxide monitoring method, such as parametric monitoring, or cannot monitor emissions at the inlet of the air pollution control device to determine percent reduction, you can apply to the executive director for approval to use an alternative monitoring method under 40 CFR §60.13(i).

Source Note: The provisions of this §113.2128 adopted to be effective May 14, 2009, 34 TexReg 2771.

View Official Rule