TITLE 30 - ENVIRONMENTAL QUALITY
PART 1 - TEXAS COMMISSION ON ENVIRONMENTAL QUALITY
CHAPTER 115 - CONTROL OF AIR POLLUTION FROM VOLATILE ORGANIC COMPOUNDS
SUBCHAPTER F - MISCELLANEOUS INDUSTRIAL SOURCES
SECTION/RULE §115.535 - Testing Requirements
Chapter Review Date 09/08/2023

(a) For the Beaumont-Port Arthur, Bexar County, Dallas-Fort Worth, El Paso, and Houston-Galveston-Brazoria areas, compliance with this division (relating to Pharmaceutical Manufacturing Facilities) shall be determined by applying the following test methods, as appropriate:(1) Test Methods 1-4 (40 Code of Federal Regulations (CFR) 60, Appendix A) for determining flow rate, as necessary;(2) Test Method 18 (40 CFR 60, Appendix A) for determining gaseous organic compound emissions by gas chromatography;(3) Test Method 25 (40 CFR 60, Appendix A) for determining total gaseous nonmethane organic emissions as carbon;(4) Test Methods 25A or 25B (40 CFR 60, Appendix A) for determining total gaseous organic concentrations using flame ionization or nondispersive infrared analysis;(5) determination of true vapor pressure using American Society of Testing and Materials (ASTM) Test Method D323-82 for the measurement of Reid vapor pressure, adjusted for actual storage temperature in accordance with API Publication 2517, Third Edition, 1989; or(6) minor modifications to these test methods approved by the executive director.(b) For Gregg, Nueces, and Victoria Counties, compliance with this division shall be determined by applying the following test methods, as appropriate:(1) Test Methods 1-4 (40 CFR 60, Appendix A) for determining flow rate, as necessary;(2) Test Method 18 (40 CFR 60, Appendix A) for determining gaseous organic compound emissions by gas chromatography;(3) Test Method 25 (40 CFR 60, Appendix A) for determining total gaseous nonmethane organic emissions as carbon;(4) Test Methods 25A or 25B (40 CFR 60, Appendix A) for determining total gaseous organic concentrations using flame ionization or nondispersive infrared analysis;(5) determination of true vapor pressure using ASTM Test Method D323-82 for the measurement of Reid vapor pressure, adjusted for actual storage temperature in accordance with API Publication 2517, Third Edition, 1989; or(6) minor modifications to these test methods approved by the executive director.

Source Note: The provisions of this §115.535 adopted to be effective February 19, 1990, 15 TexReg 549; amended to be effective August 1, 1992, 17 TexReg 4683; amended to be effective May 16, 2002, 27 TexReg 4113; amended to be effective May 16, 2024, 49 TexReg 3292.

View Official Rule